SOP of Equipment Care

        Hand piece
          Wipe air rotor and Micromotor hand piece with alcohol & cotton in between the use.
          Do not use water to clean the hand piece.
          After  the day’s  work  is over,  remove  the  hand  piece  from  the attachment,  thoroughly wipe it & clean with  alcohol alternatively we can use disinfective spray to remove blood clot etc.
          Then lubricate the handpiece as per instruction before sending it for autoclaving.
          Then put it in the pouch ready for autoclaving.
          The hand piece is ready for use.
          NEVER DROP the hand piece or the cartage will be damaged.

        Small Dental instruments like reamers, files, and  burs.
          Put the small instrument their such as burs completely dipped in alcohol immediately after use. DO NOT USE WATER to clean them.
          Root canal instruments such as reamers, files and broachers should be cleared with the aid of wire  wash  and or dipped in 5%  Sodium  Hypochlorite  to remove the  debris  ( by  efflorescence)  immediately after use.
          In between procedure sterilize the root canal instrument by means of glass bead sterilizer and keep them ready for use.
          At the end of the day burs can be autoclaved after following the ultrasonic cleaning method.
          Do not use water to clean them.
          If you find any fine instruments with damaged tips, keep them aside and DO NOT USE Them.

        Hand instruments
          Wipe them thoroughly clean using alcohol immediately after use.
          Then clean them with detergent and brush as mentioned in SOP 2
          Then put them in a tray containing multienzyme.
          Then put them in a ultrasonic cleaner.
          Then autoclave them 
          Store them ready for use.
          Take special care for mirror tops. Do not put them in water for prolonged time or they will loose their property (the silver surface  will be damaged)

        X-ray censor
          Wrap the x-ray censor with fresh cling film after every patient.
          Take optimum care NEVER TO drop it to the ground.
          Always put it attached to its designated place i.e. the x-ray box.






1 comment:

  1. Your blog specializing in going over the actual without a doubt contemptuous with on their own released coerces. Your blog aid is usually synchronize towards the fit swift. My partner and i from the weblog exuviate to supply. Clues some sort of numerous pertaining to expressing. Root Canal Specialist in Bhopal